EDL series water cooled shakers provide a superb testing platform for vibration testing on larger or heavier specimen, widely used for products of aerospace, aviation and defense, automotive and transportation.

These shakers have unique multi-cycles water cooling technique on armature coil, and improved short-circuit protection design. This features EDL series with better cooling efficiency and higher reliability. And its armature has intensity strengthened design for higher reliability and long life service. 

EDL series water cooled shakers are complying with ISO-5344, with exciting force range is from 6,000kgf to 10,000kgf, with max. payload range from 800kg to 1,200kg. The optional design on these shakers are slip tables, head expanders, multi-axis and climate chamber combination.

Features

  • Unique multi-cycles water cooling technique on armature coil 
  • Intensity strengthened armature design with reinforced material
  • Rugged suspension system and linear motion guidance
  • Double magnetic circuit design
  • Auto-centering control integrated
  • High reliability with mean time between failures(MTBF)> 10,000 hours
  • Optional foundation-free design available
  • Optional Multi-shaker and Multi-axis design available
  • Optional climate chamber combined shaker design available

Shaker Model

EDL-6000

EDL-7000

EDL-8000

EDL-10000

Rated Sine Force (kN/kgf)

60/6,000

70/7,000

80/8,000

100/10,000

Shoce Force (kN/kgf)

120/12,000

140/14,000

160/16,000

200/20,000

Usable Frequency Range (Hz)

1-2,500

1-2,500

1-2,500

1-2,500

Max. Acceleration (m/s2)

981

981

981

981

Max. Velocity (m/s)

1.8

1.8

1.8

1.8

Max. Displacement (mm, p-p)

51

51

51

76

Max. Static Payload (kg)

800

800

800

1,200

Armature Diameter (mm)

445

445

480

480

Effective Moving Elements Mass (kg)

60

60

80

85

Power Amplifier Model

VSA-H643A

VSA-H803A

VSA-H963A

VSA-H1203A

Amplifier Type

Switching

Switching

Switching

Switching

Rated Power Output (kVA)

64

80

96

120

Power Supply Requirement (kVA)

100

120

140

160

Cooling Unit Model

PCU-W60

PCU-W70

PCU-W80

PCU-W100

Internal Circle Water Flow/Pressure

40/1

40/1

50/1

50/1

External Circle Water Flow/Pressure

100/0.25-0.4

100/0.25-0.4

160/0.25-0.4

160/0.25-0.4

Distilled Water Requirement

Hardness 30ppm, PH 7-8, Conductivity 1Us/cm

Power Consumption

6

6

12

12